Bug #115077
测试 Test-ST #113421: V4.0功能与专项测试
【BSP】【EVT2】【ST】【Boot】设备开机异常断电重启,会偶现不能开机,屏幕不亮,设备没有端口,串口也没有打印日志,像没上电一样
Status: | CLOSED | Start date: | 2023-01-04 | |
---|---|---|---|---|
Priority: | High | Due date: | 2023-04-14 | |
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | BSP | |||
Target version: | VC1_FSE_0090_20230411 | |||
Need_Info: | -- | Found Version: | FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0073.X101 | |
Resolution: | FIXED | Degrated: | Yes | |
Severity: | Critical | Verified Version: | FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0086.X101 | |
Reproducibility: | Occasionally | Fixed Version: | ||
Test Type: | ST | Root cause: | 增加看门狗,避免设备跑飞
休眠唤醒逻辑修改,从边沿唤醒改为电平唤醒 |
Description
【前提条件】
None
【测试步骤】
1、烧写最新的user版本:FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0063.X101
2、设备开机后,进入Android操作界面(移除type-c)
3、插拔电源进行异常断电重启测试
【预期结果】
3. 每次设备均能正常启动
【实际结果】
3. 设备会偶现不能开机,屏幕不亮,设备没有端口,串口也没有打印日志,像没上电一般
日志中最后打印的就是断电前,重新上电的日志
工厂也出现了该问题,设备重新插拔电源后可以再次开机
History
#1 Updated by CD BSP-唐金泽 over 2 years ago
- Assignee changed from CD BSP-唐金泽 to CD BSP-陈杰
#2 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- File 屏幕不亮.zip added
补充
使用了另一个板子修改tsnv后进行复现,复现了一种场景:屏幕不亮,从断电重新上电后,没有任何日志打印
插入type-c后PC识别到了adb,并串口有日志更新,屏幕亮起在开机引导界面,已提交对应tlog、adb log、串口,不确定是否是次bug是相同问题,因为之前是user版本未开tsnv
#3 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
#4 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- File 黑屏.txt
added
#5 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
再次复现,黑屏,插入type-c后设备突然亮屏,在开机引导界面
#6 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- File 同样黑屏,但是插入type-c后没有亮屏,可以使用adb投屏tlog_iov0201017500006162025411a2212290000000841_007_0104164025.tar.gz added
再次复现,同样黑屏,但是插入type-c后没有亮屏,可以使用adb投屏
#7 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD BSP-陈杰 to CD SYSTEM-胡兵
#8 Updated by CD SYSTEM-胡兵 over 2 years ago
- Assignee changed from CD SYSTEM-胡兵 to CD BSP-杜磊
Hi 杜磊
从日志没有看出异常,建议测试复测的时候,如果出现这种情况,现场debug下display相关节点或者寄存器信息
Thanks.
#9 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- File new.zip added
#10 Updated by 物联网测试组_CDTS 段小刚 over 2 years ago
验证版本:1月18号的DB——FlatBuild_HH_VX1_MCE_FSE.M.D.user.01.00.X101.202301180547
验证结果:进行断电重启50次未复现问题
#11 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from ASSIGNED to NEED_INFO
- % Done changed from 0 to 30
#12 Updated by CD BSP-杜磊 over 2 years ago
- Due date set to 2023-02-10
- Assignee changed from CD BSP-杜磊 to 移动测试一组_CDTS 刘强
Hi, 刘强&小刚
此问题之前小刚用新的版本验证50次未复现。
1. 是否需要继续测试
2. 若未复现,是否暂时close此问题,以后复现了在reopen
#13 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from NEED_INFO to ASSIGNED
- Assignee changed from 移动测试一组_CDTS 刘强 to CD BSP-杜磊
验证版本:FlatBuild_HH_VX1_MCE_FSE.M.D.userdebug.01.00.X101.202302060240
使用当前验证继续验证50次,未复现,暂时走流程关闭次issue
麻烦修改bug状态
#14 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD BSP-杜磊 to 移动测试一组_CDTS 刘强
- % Done changed from 30 to 100
- Resolution changed from -- to FIXED
- Degrated changed from -- to Yes
#15 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from RESOLVED to VERIFY_FAILED
- Assignee changed from 移动测试一组_CDTS 刘强 to CD BSP-杜磊
验证版本:FlatBuild_HH_VX1_MCE_FSE.M.D.user.01.00.X101.202302180012
验证结果:该版本上复现一次此问题
#16 Updated by CD BSP-杜磊 over 2 years ago
- Assignee changed from CD BSP-杜磊 to CD BSP-刘川
#17 Updated by CD BSP-杜磊 over 2 years ago
- Assignee changed from CD BSP-刘川 to CD BSP-陈杰
#18 Updated by CD BSP-陈杰 over 2 years ago
此问题将到下一阶段进行修改,目前正在调查解决方案。具体是否能实现还需要进一步确认。
#19 Updated by CDTS-TEST 周婷 over 2 years ago
- Target version set to VX1_MCE_FSE_0082_20230314
#20 Updated by CD BSP-陈杰 over 2 years ago
- File FigureV0.1.0_1.mot added
- Assignee changed from CD BSP-陈杰 to CDTS_TEST 王成
- Found Version changed from FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0063.X101 to FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0073.X101
- Root cause set to 增加看门狗,避免设备跑飞
麻烦使用mot文件配合FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0073.X101版本测试。
#21 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from VERIFY_FAILED to RESOLVED
#22 Updated by CD TPM-王祥林 over 2 years ago
- Target version changed from VX1_MCE_FSE_0082_20230314 to VC1_FSE_0082_20230314
#23 Updated by CDTS_TEST 王成 over 2 years ago
- Assignee changed from CDTS_TEST 王成 to 移动测试一组_CDTS 刘强
#24 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from RESOLVED to ASSIGNED
- Assignee changed from 移动测试一组_CDTS 刘强 to CD BSP-陈杰
最新vb验证结果:
1. 过压保护后短时间内恢复正常电压,会出现无法启动的情况
2. 最新的mot V0.1.0_2 与最新vb之间混刷后,会出现反复重启的问题:https://share.thundersoft.com/redmine/issues/116789
#25 Updated by CDTS_TEST 王成 over 2 years ago
- Target version changed from VC1_FSE_0082_20230314 to VC1_FSE_0090_20230411
#26 Updated by CD BSP-杜磊 over 2 years ago
- Due date changed from 2023-02-10 to 2023-04-14
#27 Updated by CD BSP-陈杰 about 2 years ago
- Root cause changed from 增加看门狗,避免设备跑飞 to 增加看门狗,避免设备跑飞 休眠唤醒逻辑修改,从边沿唤醒改为电平唤醒
#28 Updated by CD BSP-陈杰 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD BSP-陈杰 to 移动测试一组_CDTS 刘强
- Verified Version set to FlatBuild_HH_VX1_MCE_FSE.M.R.user.01.00.0086.X101
#29 Updated by CDTS_TEST 王成 about 2 years ago
- Severity changed from Major to Critical
#30 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#31 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Status changed from VERIFIED to CLOSED